Data & Shots
Shot sets, source data, inclusion logic, quality notes, and active working sets.
Active Focus¶
{: .section-blue }
Shot 37737 — current test case for shift-correction and fmarg extraction
Time window: to be specified
Shot Registry¶
{: .section-gray }
Shot Categories¶
{: .section-purple }
[active] — current processing focus
[presentation] — used in Mike presentation
[qce] — QCE regime shots
[reference] — for method comparison
[corner-case] — known edge cases
Categorized Shot List¶
Active Focus¶
- 37737.2 [active] — current test case for shift-correction and fmarg extraction
Presentation (Mike)¶
-
39388.1 [presentation] — figure in presentation
-
39232.1 [presentation] — time windows 3.46-3.6s, 4.62-4.75s; example of not ballooning unstable
-
39237.1 [presentation] — figure in presentation
Faitsch QCE Set¶
34478, 34602, 34610, 34862, 34863, 34874, 34875, 34878, 34879, 34882, 34886, 34937, 34939, 34942, 34944, 34945, 34946, 34955, 34957, 35551, 35562, 35572, 35573, 35578, 35670, 35701 [qce]
Note: one of these is marked as "Faitsch corner case" [corner-case]
Reference Shots¶
- Lidia 2022 shots [reference] — for method parity comparison
TeSep Extraction¶
- 39388 [qce] — TeSep extracted, time range 3-5s
Faitsch Shot Set (QCE)¶
Shots extracted from Lab Notes - Feb 2026:
34478, 34602, 34610, 34862, 34863, 34874, 34875, 34878, 34879, 34882, 34886, 34937, 34939, 34942, 34944, 34945, 34946, 34955, 34957, 35551, 35562, 35572, 35573, 35578, 35670, 35701, 3606...
-
Note: Faitsch corner case mentioned
-
Processed with EQH equilibrium
Presentation Shots (Mike)¶
-
39388.1 — figure in presentation
-
39232.1 — time windows 3.46-3.6s and 4.62-4.75s
-
37737.2 — current focus
-
39237.1 — figure in presentation
Reference Shots¶
- Lidia 2022 shots — for method parity comparison
Data Sources¶
{: .section-orange }
Diagnostics¶
-
LIN — density, shift correction via ridges script
-
Thomson — temperature, shift correction via QCE database + shifts script
Databases¶
- SepOS QCE: 2024_SepOS_vSpitzer25_QCE_EDA_v1_addPlasma.dat
Equilibrium¶
- EQH — used for IDA processing and HELENA mapping
Processing Chain¶
{: .section-yellow }
LIN/Thomson (shift-corrected) -> IDA -> HELENA -> fmarg
IDA Inputs¶
- dens.in, te.in, p.in, p.out, plasma-boundary.in
HELENA Outputs¶
-
out.dat (includes alpha)
-
HELENA.xml (current density j for Ip validation)
Inclusion Criteria¶
{: .section-red }
To be defined — what makes a shot valid for this analysis?
-
Complete LIN + Thomson coverage?
-
QCE phase only?
-
Valid IDA run required?
Quality Notes¶
{: .section-red }
-
ECE diagnostic had to be turned off for IDA to process
-
inc12 has lower bound of 0.002
Shot 37737 — fmarg study windows¶
{: .section-blue }
Selected time intervals for fmarg extraction/highlighted overview analysis:
plain text
0.7-0.9, 1.1-1.3, 1.6-1.8, 2-2.2, 2.75-2.95, 3.35-3.55, 3.7-3.9, 4-4.2, 4.5-4.7, 4.8-5, 5.55-5.75, 6.3-6.5, 6.6-6.8, 6.9-7.1, 7.4-7.6, 7.7-7.9, 8.15-8.25