Skip to content

Data & Shots

**Status:** Active working set **Vibe:** Registry and processing map for current shot-selection work. **Stakeholder:** Jessica

Shot sets, source data, inclusion logic, quality notes, and active working sets.

Active Focus

{: .section-blue }

Shot 37737 — current test case for shift-correction and fmarg extraction

Time window: to be specified

Shot Registry

{: .section-gray }

Shot Categories

{: .section-purple }

[active] — current processing focus

[presentation] — used in Mike presentation

[qce] — QCE regime shots

[reference] — for method comparison

[corner-case] — known edge cases

Categorized Shot List

Active Focus

  • 37737.2 [active] — current test case for shift-correction and fmarg extraction

Presentation (Mike)

  • 39388.1 [presentation] — figure in presentation

  • 39232.1 [presentation] — time windows 3.46-3.6s, 4.62-4.75s; example of not ballooning unstable

  • 39237.1 [presentation] — figure in presentation

Faitsch QCE Set

**Reference Set** — historical QCE shots used for comparison and extraction context.

34478, 34602, 34610, 34862, 34863, 34874, 34875, 34878, 34879, 34882, 34886, 34937, 34939, 34942, 34944, 34945, 34946, 34955, 34957, 35551, 35562, 35572, 35573, 35578, 35670, 35701 [qce]

Note: one of these is marked as "Faitsch corner case" [corner-case]

Reference Shots

  • Lidia 2022 shots [reference] — for method parity comparison

TeSep Extraction

  • 39388 [qce] — TeSep extracted, time range 3-5s

Faitsch Shot Set (QCE)

Shots extracted from Lab Notes - Feb 2026:

34478, 34602, 34610, 34862, 34863, 34874, 34875, 34878, 34879, 34882, 34886, 34937, 34939, 34942, 34944, 34945, 34946, 34955, 34957, 35551, 35562, 35572, 35573, 35578, 35670, 35701, 3606...

  • Note: Faitsch corner case mentioned

  • Processed with EQH equilibrium

Presentation Shots (Mike)

  • 39388.1 — figure in presentation

  • 39232.1 — time windows 3.46-3.6s and 4.62-4.75s

  • 37737.2 — current focus

  • 39237.1 — figure in presentation

Reference Shots

  • Lidia 2022 shots — for method parity comparison

Data Sources

{: .section-orange }

Diagnostics

  • LIN — density, shift correction via ridges script

  • Thomson — temperature, shift correction via QCE database + shifts script

Databases

  • SepOS QCE: 2024_SepOS_vSpitzer25_QCE_EDA_v1_addPlasma.dat

Equilibrium

  • EQH — used for IDA processing and HELENA mapping

Processing Chain

{: .section-yellow }

LIN/Thomson (shift-corrected) -> IDA -> HELENA -> fmarg

IDA Inputs

  • dens.in, te.in, p.in, p.out, plasma-boundary.in

HELENA Outputs

  • out.dat (includes alpha)

  • HELENA.xml (current density j for Ip validation)

Inclusion Criteria

{: .section-red }

To be defined — what makes a shot valid for this analysis?

  • Complete LIN + Thomson coverage?

  • QCE phase only?

  • Valid IDA run required?

Quality Notes

{: .section-red }

  • ECE diagnostic had to be turned off for IDA to process

  • inc12 has lower bound of 0.002

Shot 37737 — fmarg study windows

{: .section-blue }

Selected time intervals for fmarg extraction/highlighted overview analysis:

plain text 0.7-0.9, 1.1-1.3, 1.6-1.8, 2-2.2, 2.75-2.95, 3.35-3.55, 3.7-3.9, 4-4.2, 4.5-4.7, 4.8-5, 5.55-5.75, 6.3-6.5, 6.6-6.8, 6.9-7.1, 7.4-7.6, 7.7-7.9, 8.15-8.25